SRL 80 °C Self Limiting Parallel Heating Tape SRL
Self-Regulating Heating Cable - SRL 80 °C Self Limiting Parallel Heating Tape SRL
Chromalox SRL self-regulating heating cable provides safe, reliable heat tracing for freeze protection of pipes, valves, tanks and similar applications.
SRL 80 °C Self Limiting Parallel Heating Tape SRL
Features:
- Energy efficient, self-regulating SRL uses less energy when less heat is required.
- Easy to install, SRL can be cut to any length (up to max. circuit length) in the field
- Field splices can be performed easily in minutes with no scrap or wasted cold sections.
- SRL features lower installed cost than steam tracing, less maintenance expense and less downtime
- SRL can be overlapped without burnout, which simplifies heat tracing of in-line process equipment such as valves, elbows and pumps.
- Because SRL is self-regulating, over-temperature conditions are minimized.
- Chromalox termination, splice, tee and end seal kits reduce installation time
Approvals:
ATEX and IECEX Exe IIGb, Factory Mutual (FM) Approved for ordinary areas. UL Listed, CSA Certified for ordinary areas. UL listed for freeze protection of fire protection system piping. FM Approved for hazardous (classified) areas when used with U Series, DL and EL accessories:
- Class I, Div. 2, Groups B, C, D (gases, vapors)
- Class II, Div. 2, Groups F, G (combustible dust)
- Class III, Div. 2 (easily ignitable fibers and fillings)
- 3 Watt Rated T6 Temperature Class
- 5 and 8 Watt Rated T5 Temperature Class
- 10 Watt Rated T4A Temperature Class.
CSA Certified for hazardous areas when used with DL, EL or U Series accessories:
• Class I, Div. 2, Groups A, B, C, D
• Class II, Div. 2, Groups F, G.
• ATEX and IECEX Exe IIGb
• IIG Exe II
- Self-Regulating, Energy Efficient
- 16 AWG Buss Wire
- Circuit Lengths to 660 Feet
- Process Temperature Maintenance to 150°F (65°C)
- Maximum Continuous Exposure Temperature, Power Off, 185°F (85°C)
- Industrial Freeze Protection Applications
- Freeze Protection of Fire Protection System Piping
- Field Splicing Without Disrupting Heat Output
- 3, 5, 8 and 10 W/Ft.
- 120 and 208 - 277 Volt From Stock
- Approximate Size 3/8”W x 1/8"H
- Min. Bend Radius 1-1/8"
- For Use on Metal and Plastic Pipes
Application:
- Industrial Freeze Protection Applications
- Fire Protection System Pipe Freeze Protection
- Pipeline Freeze Protection
- Tank and Valve Freeze Protection
- Process Equipment Freeze Protection
- Chemical Pipeline Heating
- Refinery Equipment Freeze Protection
- Platform Equipment Freeze Protection
- Heating of Pipes and Tanks in Power Plants
- Temperature Protection of Oil Lines in Food Processing Plants
- Freeze Protection of Drainage Lines in Large Kitchens
- Applications in Explosive Atmospheres (Thanks to Ex-proof Feature)
SRL 80 °C Self Limiting Parallel Heating Tape SRL
| 1) Double 16 AWG Copper Bus Wires | Provides reliable electrical current capacity. |
| 2) Semiconductor Polymer Core Matrix | The “Self-Regulating” component of the cable, the electrical resistance varies with temperature. As the operating temperature decreases, the core's heat output increases; as the operating temperature increases, the heat output decreases. |
| 3) Polyolefin Jacket | Flame retardant, electrically insulates the matrix and bus wires, and provides resistance to water and some inorganic chemical solutions. |
| 4) Tinned Copper Braid | Provides additional mechanical protection and a positive ground path in any environment. |
| 5) High-Temperature Fluoropolymer or TPR Outer Jacket (optional) | Corrosion-resistant, flame-retardant outer jacket is highly effective in many environments. TPR coatings provide protection against certain inorganic chemical solutions. Fluoropolymer coatings are used for exposure to organic or corrosive solutions. These coatings also provide protection against abrasion and impact damage. |

SRL 80 °C Self Limiting Parallel Heating Tape SRL
Features:
- Energy efficient, self-regulating SRL uses less energy when less heat is required.
- Easy to install, SRL can be cut to any length (up to max. circuit length) in the field
- Field splices can be performed easily in minutes with no scrap or wasted cold sections.
- SRL features lower installed cost than steam tracing, less maintenance expense and less downtime
- SRL can be overlapped without burnout, which simplifies heat tracing of in-line process equipment such as valves, elbows and pumps.
- Because SRL is self-regulating, over-temperature conditions are minimized.
- Chromalox termination, splice, tee and end seal kits reduce installation time
Approvals:
ATEX and IECEX Exe IIGb, Factory Mutual (FM) Approved for ordinary areas. UL Listed, CSA Certified for ordinary areas. UL listed for freeze protection of fire protection system piping. FM Approved for hazardous (classified) areas when used with U Series, DL and EL accessories:
- Class I, Div. 2, Groups B, C, D (gases, vapors)
- Class II, Div. 2, Groups F, G (combustible dust)
- Class III, Div. 2 (easily ignitable fibers and fillings)
- 3 Watt Rated T6 Temperature Class
- 5 and 8 Watt Rated T5 Temperature Class
- 10 Watt Rated T4A Temperature Class.
CSA Certified for hazardous areas when used with DL, EL or U Series accessories:
• Class I, Div. 2, Groups A, B, C, D
• Class II, Div. 2, Groups F, G.
• ATEX and IECEX Exe IIGb
• IIG Exe II
- Self-Regulating, Energy Efficient
- 16 AWG Buss Wire
- Circuit Lengths to 660 Feet
- Process Temperature Maintenance to 150°F (65°C)
- Maximum Continuous Exposure Temperature, Power Off, 185°F (85°C)
- Industrial Freeze Protection Applications
- Freeze Protection of Fire Protection System Piping
- Field Splicing Without Disrupting Heat Output
- 3, 5, 8 and 10 W/Ft.
- 120 and 208 - 277 Volt From Stock
- Approximate Size 3/8”W x 1/8"H
- Min. Bend Radius 1-1/8"
- For Use on Metal and Plastic Pipes
Application:
- Industrial Freeze Protection Applications
- Fire Protection System Pipe Freeze Protection
- Pipeline Freeze Protection
- Tank and Valve Freeze Protection
- Process Equipment Freeze Protection
- Chemical Pipeline Heating
- Refinery Equipment Freeze Protection
- Platform Equipment Freeze Protection
- Heating of Pipes and Tanks in Power Plants
- Temperature Protection of Oil Lines in Food Processing Plants
- Freeze Protection of Drainage Lines in Large Kitchens
- Applications in Explosive Atmospheres (Thanks to Ex-proof Feature)
