In series resistance cables, the part that carries energy and the part that generates heat are the same, consisting of a chromium-nickel wire. These cables can be produced with different resistance values and are commonly used for heat tracing in long pipelines. The resistance of these cables is directly proportional to their length.
To prevent excessive increases in current passing through them, there is a minimum length limitation for their use. The appropriate resistance must be selected based on the required length and power. Depending on the required power, temperature values, and environmental conditions, the insulation material used may vary—from PVC to PTFE and even glass fiber for dry locations.
These cables can be used at temperatures of up to 260°C and 450°C, while metal-sheathed, mineral-insulated versions can withstand temperatures up to 1000°C.
Eltherm ELKM-AG-L insulated resistance heating cables provide process temperature maintenance and frost protection to vessels, pipes, valves, IBC’s and tanks up to 260° Celsius.
Applications:
Advantages:
The ELKM-AS series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 260°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 260°C heat resistance, the ELKM-AS series provides a reliable solution for industrial heating applications.
ADVANTAGES:
FIELDS OF APPLICATION:
The ELKM-AE series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 260°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 260°C heat resistance, the ELKM-AE series provides a reliable solution for industrial heating applications.
ADVANTAGES:
FIELDS OF APPLICATION:
EKL medium is an extremely flexible heating cable with a fixed specific resistance. Thanks to its small outer dimensions, the heating cable can be easily installed even on irregularly objects such as pumps, valves and flanges. The heating cable can be easily tailored on sites and made even easier by the imprinted metre markings.
EKL premium is a flexible heating cable with a fixed specific resistance. It’s small external dimensions make the heating cable easy to install, even on irregularly shaped surfaces such as on pumps, valves and flanges. Assembly on sites is simple and made even easier by the imprinted metre markings. The reinforced structure facilitates applications of the EKL premium heating cable even under increased mechanical stress (7 Joule).
The ELKM-AG series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 250°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 250°C heat resistance, the ELKM-AG series provides a reliable solution for industrial heating applications.
ADVANTAGES:
APPLICATIONS:
The ELKM-AG-E series series resistance cables feature a chromium-nickel wire structure where the energy-carrying and heat-generating components are the same. Designed for safe operation at temperatures up to 260°C, these cables can be manufactured with different resistance values and are widely used for heat tracing in long pipelines. Their resistance is directly proportional to their length.
To prevent excessive current flow, there is a minimum length limitation for their use. Selecting the appropriate resistance value is essential for optimal performance and energy efficiency. Depending on required power, temperature levels, and environmental conditions, the insulation material can vary from PVC to PTFE. With its 260°C heat resistance, the ELKM-AG-E series provides a reliable solution for industrial heating applications.
ADVANTAGES:
APPLICATION:
The EKL Connection Technology is a connection system for EKL medium and EKL premium for use in potentially explosive atmospheres. Depending on the design, the ECT connection technology may be used to connect a cold lead or to connect two heating cables. Butt connectors, which ensure a reliable and permanent connection, are used for the electrical connection of the heating wire and the protective braid. Using pre-assembled cold leads and our connection technology, complete heating circuits can be constructed quickly and flexibly.
Applications :
Advantages :
Polyester enclosures have proven their worth in many industrial plants. They offer safe protection even when they are used under extremely unfavorable conditions, on exposure to aggressive chemical media or hard mechanical conditions. The inside base of the enclosure has at its sides, threaded bushings for the fastening of mounting rails or panels. The enclosure is mounted by means of insulated screws outside of the lid seal.