Quotation Basket

Satellite Antenna De-icing Systems

  • Home
  • Satellite Antenna De-icing Systems

Antenna Heating Cables - Satellite Antenna De-icing Systems

De-icing system consists of a factory pre-wired control unit, heater pads for reflector coverage, and a feedhorn heater. All systems are engineered to be easily assembled, installed and operated.

Satellite Antenna De-icing Systems

The Viking SATCOM De-icing system consists of a factory pre-wired control unit, heater pads for reflector coverage, and a feedhorn heater. All systems are engineered to be easily assembled, installed and operated.

The control unit has three modes of operation: Automatic, Manual Off and Manual On. The Automatic mode allows the control to monitor the ambient temperature and sense the presence of moisture. An ambient temperature of less than 40 degrees F and the presence of moisture activate a heater contactor. The heater contactor is rated up to 50 amps. The heaters will remain on for a factory preset time of one hour longer than conditions warrant. The Manual Off mode turns the heaters off, regardless of the weather conditions. The Manual On mode turns the heaters on, regardless of the weather conditions. Control units are factory preset to operate on 120 to 240 volts, single or three phase power. All cabling to attach the heater pads is factory pre-wired. The larger systems have a control unit with remote moisture sensor.

The heater pads consist of heater wire sandwiched between layers of aluminum foil. Heater pads allow for a faster install without the need for templates. The aluminum foil is coated with an aggressive acrylic adhesive and a peel and stick liner. Watt density of the heater pads, depending on the reflector, is between 40 and 55 watts per square foot. The aggressive acrylic adhesive adheres to a variety of substrates and will not release when pad temperature increases. Heater pads have water resistant connectors that plug into the cables from the control unit.

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn. Installation of the de-ice system consists of applying the heater pads to the backside of the reflector, mounting the control unit / moisture sensor, routing power to the control unit, attaching the feedhorn heater, and connecting the heater pads to the control cables. The De-icing systems can be custom made for a variety of antennas and applications.

Application Areas:

  • Satellite communication systems
  • Radio telescopes
  • Weather stations
  • All kinds of satellite antenna applications

Satellite Antenna De-icing Systems

  • Automatic De-icing System for Protection against Snow and Ice
  • Simple to Field Install and Operate
  • Engineered for Customer Specified Voltages
  • Low Energy Costs
  • User selectable Automatic, Off or Manual On Modes
  • Available for DH Satellite Reflector Sizes: 1.8, 2.4, 3.0, 3.3, 3.7, 3.8, 3.9, 4.2, 4.5 and 5.0 Meter

Satellite Antenna De-icing Systems

The Viking SATCOM De-icing system consists of a factory pre-wired control unit, heater pads for reflector coverage, and a feedhorn heater. All systems are engineered to be easily assembled, installed and operated.

The control unit has three modes of operation: Automatic, Manual Off and Manual On. The Automatic mode allows the control to monitor the ambient temperature and sense the presence of moisture. An ambient temperature of less than 40 degrees F and the presence of moisture activate a heater contactor. The heater contactor is rated up to 50 amps. The heaters will remain on for a factory preset time of one hour longer than conditions warrant. The Manual Off mode turns the heaters off, regardless of the weather conditions. The Manual On mode turns the heaters on, regardless of the weather conditions. Control units are factory preset to operate on 120 to 240 volts, single or three phase power. All cabling to attach the heater pads is factory pre-wired. The larger systems have a control unit with remote moisture sensor.

The heater pads consist of heater wire sandwiched between layers of aluminum foil. Heater pads allow for a faster install without the need for templates. The aluminum foil is coated with an aggressive acrylic adhesive and a peel and stick liner. Watt density of the heater pads, depending on the reflector, is between 40 and 55 watts per square foot. The aggressive acrylic adhesive adheres to a variety of substrates and will not release when pad temperature increases. Heater pads have water resistant connectors that plug into the cables from the control unit.

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn. Installation of the de-ice system consists of applying the heater pads to the backside of the reflector, mounting the control unit / moisture sensor, routing power to the control unit, attaching the feedhorn heater, and connecting the heater pads to the control cables. The De-icing systems can be custom made for a variety of antennas and applications.

Application Areas:

  • Satellite communication systems
  • Radio telescopes
  • Weather stations
  • All kinds of satellite antenna applications

Best Selling Products


Insulation Entry Kits

Insulation Entry Kits

EHT Mühendislik
Heat Trace Insulation Caution Labels

Heat Trace Insulation Caution Labels

EHT Mühendislik
Mounting Plates And Brackets In Stainless Steel

Mounting Plates And Brackets In Stainless Steel

EHT Mühendislik
Mounting Plates And Brackets In Galvanised Steel

Mounting Plates And Brackets In Galvanised Steel

EHT Mühendislik
Cold Room EHTPxx Heat Tracing Control Panel

Cold Room EHTPxx Heat Tracing Control Panel

EHT Mühendislik
Small Tank Flange (STFX) Heaters

Small Tank Flange (STFX) Heaters

EHT Mühendislik
Large Tank Flange (LTFX) Heaters

Large Tank Flange (LTFX) Heaters

EHT Mühendislik
Unitary Immersion (RSTO) Heaters

Unitary Immersion (RSTO) Heaters

EHT Mühendislik
Flexible Tank (FXTH) Heaters

Flexible Tank (FXTH) Heaters

EHT Mühendislik
Screw Plug Immersion Heaters

Screw Plug Immersion Heaters

EHT Mühendislik
Over-the-Side Immersion Heaters

Over-the-Side Immersion Heaters

EHT Mühendislik
Flanged Immersion Heaters

Flanged Immersion Heaters

EHT Mühendislik
Circulation Heaters

Circulation Heaters

EHT Mühendislik
Heat Transfer Systems

Heat Transfer Systems

EHT Mühendislik
Fastening Strips

Fastening Strips

EHT Mühendislik
Mosque EHTPxx Heat Tracing Control Panel

Mosque EHTPxx Heat Tracing Control Panel

EHT Mühendislik
Heat Trace EHTPxx Heat Tracing Control Panel

Heat Trace EHTPxx Heat Tracing Control Panel

EHT Mühendislik
Heated Insulation Jacket

Heated Insulation Jacket

EHT Mühendislik
Plasterboard Case Deep Case

Plasterboard Case Deep Case

EHT Mühendislik
Fastening Strip

Fastening Strip

EHT Mühendislik
EHTPxx Heat Tracing Control Panel

EHTPxx Heat Tracing Control Panel

EHT Mühendislik
EHT-Flexicon

EHT-Flexicon

EHT Mühendislik
tesa® 50600 - Green Polyester/Silicone Masking Tape

tesa® 50600 - Green Polyester/Silicone Masking Tape

EHT Mühendislik
EHT-FD Wall-Mounted Electronic Temperature Controller

EHT-FD Wall-Mounted Electronic Temperature Controller

EHT Mühendislik
Custom-Made Insulation Jackets

Custom-Made Insulation Jackets

EHT Mühendislik
Message on WhatsApp Call Us Now Get Directions